WT 160 Photoelectric Proximity Switch, Background Suppression, Red Light -- DC Scanning distance 4 . . . 55 mm Photoelectric proximity switch Dimensional drawing 11 WT 160 . . .1. 1 2 9.45 38 4.2 3.3 Horizontal and vertical models Focussed scanner 9 7.4 23 o4.2 3 9.45 o4.2 3 www..com Setting options All types 1 2 3 4 5 Optics center, receiver Optics center, transmitter Plug M 8 or connection cable Sensitivity control Light/dark rotary switch: L = light switching D = dark switching 6 Orange LED indicator (Status output) 7 Green LED signal strength indicator (Operating reserve) D 7 L 4 5 6 CRsV Accessories Cable receptacles Mounting bracket (included) Connection type WT 160-E112 WT 160-E122 WT 160-F112 WT 160-F122 WT 160-E310 WT 160-E320 WT 160-F310 WT 160-F320 WT 160-E410 WT 160-E420 WT 160-F410 WT 160-F420 3 x 0.2 mm2 brn blu blk 3 pin, M 8 brn blu blk 4 pin, M 8 L+ M Q 1 3 4 L+ M Q brn blu blk wht 1 3 4 2 10 2 11.5 7.5 1 38 15.4 8.1 with background suppression and great sensitivity Contamination control with green LED indicator and contamination control output 10 15.4 8.1 WT 160 . . . 2. 3 11 23 L+ M Q NC NC = not connected 2 SENSICK WT 160 Specifications Housing shape Scanning distance, typ. max. Operating scanning distance Background suppression Adjustable sensitivity Light source2), light type Light spot diameter Transmitter dispersion angle Supply voltage VS Residual ripple4) Current consumption5) Switching outputs Horizontal Vertical 4 ... 55 mm 1) 8 ... 50 mm1) From approx. 100 mm Potentiometer, 2 rotations w. scaling 270 LED, red light Approx. 3 mm at 25 mm distance Focussed, focus 25 mm DC 10 ... 30 V 3) 10 % 25 mA PNP, open collector: Q NPN, open collector: Q 100 mA Light/dark switching per rotary switch 0.5 ms / 1000/s PVC, 2 m 8); 3 x 0.2 mm2, o 4.2 mm 3 pin, M 8 4 pin, M 8 WT 160F112 F310 F410 E112 E310 E410 F122 F320 F420 E122 E320 E420 www..com Output current IA max. Light receiver, switching type Response time6)/Max. switching frequ.7) Connection type: connection cable plug plug VDE protection class9) Protection circuits10) Enclosure rating Ambient temperature Weight Housing material V A, B, C, D IP 67 Operation - 25 ... + 55 C Storage - 40 ... + 70 C With connection cable approx. 60 g With plug approx. 20 g Housing: PBT; optics: PMMA 1) Scanned material with 90 % reflectance (with reference to standard white according to DIN 5033) 2) Average service life 100,000 h at TU = + 25 C 3) Limit values 4) May not exceed or fall short of VS tolerances 5) Without load 16) Signal operating time with ohmic load 17) With light/dark ratio 1:1 08) Do not bend connection cable below 0 C 09) Rated voltage DC 50 V 10) A = VS connections reverse-polarity protected B = Inputs and outputs reverse-po larity protected C = Interference pulse suppression D = Outputs overload and shortcircuit protected Scanning distance Ordering information Type WT 160-F112 WT 160-F310 WT 160-F410 WT 160-F122 WT 160-F320 WT 160-F420 WT 160-E112 WT 160-E310 WT 160-E410 WT 160-E122 WT 160-E320 2 3 WT 160-E420 Order no. 6 022 783 6 022 787 6 022 788 6 022 785 6 022 789 6 022 790 6 022 775 6 022 779 6 022 780 6 022 777 6 022 781 6 022 782 1 2 3 48 68 8 10 30 35 40 45 50 55 100 0 (mm) 10 20 30 40 50 60 Operating scanning distance Typ. max. scanning distance 1 Scanning range on white, 90 % reflectance 2 Scanning range on gray, 18 % reflectance 3 Scanning range on black, 6 % reflectance 1 10 Operating reserve 1 0 (mm) Scanning range 50 Operating range SENSICK 3 WT 160 Photoelectric Proximity Switch, Energetic, Red Light -- DC Scanning distance 0 . . . 900 mm Photoelectric proximity switch Dimensional drawing 11 WT 160 . . . 7. 1 2 9.45 38 4.2 3.3 Horizontal and vertical models Energetic scanner for 9 7.4 23 o4.2 3 9.45 o4.2 3 www..com Setting options All types 1 2 3 4 5 Optics center, receiver Optics center, transmitter Plug M 8 or connection cable Sensitivity control Light/dark rotary switch: L = light switching D = dark switching 6 Orange LED indicator (Status output) 7 Green LED signal strength indicator (Operating reserve) D 7 L 4 5 6 CRsV Connection type WT 160-E172 WT 160-E182 WT 160-F172 WT 160-F182 WT 160-E370 WT 160-E380 WT 160-F370 WT 160-F380 WT 160-E470 WT 160-E480 WT 160-F470 WT 160-F480 Accessories Cable receptacles Mounting bracket (included) 3 x 0.2 mm2 brn blu blk 3 pin, M 8 brn blu blk 4 pin, M 8 L+ M Q 1 3 4 L+ M Q brn blu blk wht 1 3 4 2 10 2 11.5 7.4 1 38 15.4 8.1 standard applications Contamination control with green LED indicator and contamination control output 10 15.4 8.1 WT 160 . . . 8. 3 11 23 L+ M Q NC NC = not connected 4 SENSICK WT 160 Specifications Housing shape Scanning distance, typ. max. Operating scanning distance Adjustable sensitivity Light source2), light type Light spot diameter Transmitter dispersion angle Supply voltage VS Residual ripple4) Current consumption5) Switching outputs Horizontal Vertical 0 ... 900 mm 1) 0 ... 800 mm1) Potentiometer, 2 rotations w. scaling 270 LED, red light Approx. 90 mm at 500 mm distance Approx. 4.8 DC 10 ... 30 V 3) 10 % 25 mA WT 160F172 F370 F470 E172 E370 E470 F182 F380 F480 E182 E380 E480 PNP, open collector: Q NPN, open collector: Q Output current IA max. 100 mA www..com type Light receiver, switching Light/dark switching per rotary switch Response time6)/ Max. switching frequ.7) 0.5 ms / 1000/s Connection type: connection cable plug plug VDE protection class9) Protection circuits10) Enclosure rating Ambient temperature Weight Housing material PVC, 2 m 8); 3 x 0.2 mm2, o 4.2 mm 3 pin, M 8 4 pin, M 8 V A, B, C, D IP 67 Operation - 25 ... +55 C Storage - 40 ... +70 C With connection cable approx. 60 g With plug approx. 20 g Housing: PBT; optics: PMMA 1) Scanned material with 90 % reflectance (with reference to standard white according to DIN 5033) 2) Average service life 100,000 h at TU = +25 C 3) Limit values 4) May not exceed or fall short of VS tolerances 5) Without load 6) Signal operating time with ohmic load 7) With light/dark ratio 1:1 18) Do not bend connection cable below 0 C 109) Rated voltage DC 50 V 10) A = VS connections reverse-polarity protected B = Inputs and outputs reversepolarity protected C = Interference pulse suppression D = Outputs overload and shortcircuit protected Scanning distance Ordering information Type WT 160-F172 WT 160-F370 WT 160-F470 WT 160-F182 WT 160-F380 WT 160-F480 WT 160-E172 WT 160-E370 WT 160-E470 WT 160-E182 WT 160-E380 2 3 WT 160-E480 Order no. 6 022 815 6 022 819 6 022 820 6 022 817 6 022 821 6 022 822 6 022 807 6 022 811 6 022 812 6 022 809 6 022 813 6 022 814 1 2 3 0 0 45 350 400 250 300 800 900 100 0 (mm) 250 500 750 1000 1 Operating scanning distance Typ. max. scanning distance 1 Scanning range on white, 90 % reflectance 2 Scanning range on gray, 18 % reflectance 3 Scanning range on black, 6 % reflectance 10 Operating reserve 1 0 (mm) 500 Operating range 1000 Scanning range SENSICK 5 WT 160 Photoelectric Proximity Switch, Divergent Optics, Red Light -- DC Scanning distance 0 . . . 105 mm Photoelectric proximity switch Dimensional drawing 11 WT 160 . . . 5. 1 2 9.45 38 4.2 3.3 Horizontal and vertical models Scanner with large opening 9 7.4 23 o4.2 3 9.45 o4.2 3 www..com Setting options All types 1 2 3 4 5 Optics center, receiver Optics center, transmitter Plug M 8 or connection cable Sensitivity control Light/dark rotary switch: L = light switching D = dark switching 6 Orange LED indicator (Status output) 7 Green LED signal strength indicator (Operating reserve) D 7 L 4 5 6 CRsV Connection type WT 160-E152 WT 160-E162 WT 160-F152 WT 160-F162 WT 160-E350 WT 160-E360 WT 160-F350 WT 160-F360 WT 160-E450 WT 160-E460 WT 160-F450 WT 160-F460 Accessories Cable receptacles Mounting bracket (included) 3 x 0.2 mm2 brn blu blk 3 pin, M 8 brn blu blk 4 pin, M 8 L+ M Q 1 3 4 L+ M Q brn blu blk wht 1 3 4 2 10 2 11.5 7.4 1 38 15.4 8.1 angle for detecting objects conveyed loosely Contamination control with green LED indicator and contamination control output 10 15.4 8.1 WT 160 . . . 6. 3 11 23 L+ M Q NC NC = not connected 6 SENSICK WT 160 Specifications Housing shape Scanning distance, typ. max. Operating scanning distance Adjustable sensitivity Light source3), light type Light spot diameter Transmitter dispersion angle Supply voltage VS Residual ripple5) Current consumption6) Switching outputs Horizontal Vertical 0... 105 mm1)2) 0 ... 100 mm1)2) Potentiometer, 2 rotations w. scaling 270 LED, red light Approx. 100 mm at 100 mm distance Approx. 40 DC 10 ... 30 V 4) 10 % 25 mA WT 160F152 F350 F450 E152 E350 E450 F162 F360 F460 E162 E360 E460 PNP, open collector: Q NPN, open collector: Q Output current IA max. 100 mA www..com type Light receiver, switching Light/dark switching per rotary switch Response time7)/ Max. switching frequ.8) 0.5 ms / 1000/s Connection type: connection cable plug plug VDE protection class10) Protection circuits11) Enclosure rating Ambient temperature Weight Housing material PVC, 2 m 9); 3 x 0.2 mm2, o 4.2 mm 3 pin, M 8 4 pin, M 8 V A, B, C, D IP 67 Operation -25 ... +55 C Storage -40 ... +70 C With connection cable approx. 60 g With plug approx. 20 g Housing: PBT; optics: PMMA 1) Scanned material with 90 % reflectance (with reference to standard white according to DIN 5033) 2) Object size 30 x 30 mm 3) Average service life 100,000 h at TU = +25 C 4) Limit values 5) May not exceed or fall short of VS tolerances 6) Without load 17) Signal operating time with ohmic load 11) A = 18) With light/dark ratio 1:1 09) Do not bend connection cable B= below 0 C 10) Rated voltage DC 50 V C= D= VS connections reverse-polarity protected Inputs and outputs reversepolarity protected Interference pulse suppression Outputs overload and shortcircuit protected Scanning distance Ordering information Type WT 160-F152 WT 160-F350 WT 160-F450 WT 160-F162 WT 160-F360 WT 160-F460 WT 160-E152 WT 160-E350 WT 160-E450 WT 160-E162 WT 160-E360 WT 160-E460 Order no. 6 022 799 6 022 803 6 022 804 6 022 801 6 022 805 6 022 806 6 022 791 6 022 795 6 022 796 6 022 793 6 022 797 6 022 798 1 2 3 0 0 0 3 6 25 30 50 55 95 105 100 20 30 40 50 60 70 80 90 100 110 (mm) Operating scanning distance Typ. max. scanning distance 1 Scanning range on white, 90 % reflectance 2 Scanning range on gray, 18 % reflectance 3 Scanning range on black, 6 % reflectance 1 10 Operating reserve 2 1 3 Operating range 50 100 0 (mm) Scanning range SENSICK 7 |
Price & Availability of WT160 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |